Xantech Network Card MRC44CB1 User Manual

Page 1  
Model MRC44CB1  
INSTALLATION INSTRUCTIONS  
MODEL MRC44CB1  
MRC SERIES CONNECTING BLOCK  
CONTROLLER  
KEYPAD  
LED1  
JP1  
TABLE OF CONTENTS  
INTRODUCTION..................................................................................................................................................................1  
Features..........................................................................................................................................................................1  
Specifications...................................................................................................................................................................1  
INSTALLATION....................................................................................................................................................................2  
Example A - Substituting A Smartpad3, Waterpad Keypad, or IR Receiver In Place Of A MRC44 Keypad ..........................2  
Example B - Substituting A Secondary Sub-Zone MRC44 Keypad With A Smartpad3, Waterpad Keypad or IR Receiver ....2  
Example C - Adding An IR Receiver To A Zone With An MRC44 Keypad...........................................................................3  
Example D - Extending The Overall Length Between MRC44 Keypads..............................................................................4  
TROUBLESHOOTING..........................................................................................................................................................4  
INTRODUCTION  
The MRC44CB1 connecting block allows added flexibility for current MRC44 system owners in regard to Keypad placement. It  
also provides for the addition of external IR Receivers and/or utilizing other Xantech IR Keypads on an existing MRC44  
system (i.e. using SMARTPAD3 or WATERPAD Keypads in addition to or instead of, the standard MRC Controller Keypads).  
FEATURES  
Add external Xantech IR Receivers in conjunction with MRC44 Keypads  
For Retro installs requiring J-Box style keypads only, allows integration of SMARTPAD3 or WATERPAD Keypads to an  
existing MRC44 system  
Add outdoor Zone or Sub-Zone utilizing WATERPAD Keypad  
Extend maximum distance of Secondary Keypad to 600ft  
External Power Supply selector jumper. Enables use of external 12v supply for longer cable runs and applications requiring  
higher current capacity supplies  
IR Receive confirmation LED  
SPECIFICATIONS  
1 – Three Terminal, Screw-Type connection for +12VDC, GND, and SIGnal from Xantech IR Receivers and IR Controller  
Keypads  
1 – 3.5mm mini stereo “Quick Connect” IR IN input jack  
2.1mm coaxial power jack  
2 – RJ45 connectors for connection to/from MRC Controller and MRC44 Keypad  
Max Distance powered from MRC44 Controller: 200ft as measured from MRC44 Controller to last keypad/IR Receiver in  
line  
Max Distance powered fro external 782-00 PS: 600ft as measured from MRC44 Controller to last keypad/IR Receiver in  
line.  
Dimensions: 3-½” W x 1” D x ¾”H  
© 2002 Xantech Corporation  
 
Model MRC44CB1  
Page 3  
3. If overall distance from MRC44 Controller to secondary zone location is less than 200ft., you may power Secondary  
Keypad/IR Receiver from the Primary Keypad. In this case, install a jumper across JP1 on the MRC44CB1  
Connecting block.  
Note: If overall distance from MRC44 to secondary zone is greater than 200ft., an external 781RG power supply  
will be required. In this case REMOVE JUMPER across JP1 on MRC44CB1 and connect supply to 2.5mm coaxial  
jack.  
4. Properly terminate wire with RJ45 connector and connect to the connector labeled Controller on the MRC44CB1  
5. Run 3-conductor wire from MRC44CB1 Connecting block location to Secondary Keypad or IR Receiver location.  
6. Connect one end of the 3-conductor cable to the V G S terminals of the MRC44CB1 connecting block and the other  
end to the proper +12v, IR Out, and GND terminals of the desired Keypad or IR Receiver.  
Note: If IR Receiver is being connected with a 3.5mm ‘Quick Connect’ plug, simply insert plug into jack labeled IR  
IN on MRC44CB1  
781RG Power Supply  
IR Receiver  
MRC44CB1  
CONTROLLER  
KEYPAD  
LED1  
C
JP1  
POWER  
POWER  
MRC44  
POWER  
1
2
3
4
CH  
VOL  
VOL  
CH  
VOL  
VOL  
PAUSE  
PAUSE  
FOUR ZONE - FOUR SOURCE AUDIO/VIDEO CONTROLLER/AMPLIFIER  
SELECT  
PLAY  
SELECT  
PLAY  
CH  
CH  
REW  
FF  
REW  
FF  
STOP  
STOP  
STATUS  
MUTE  
STATUS  
MUTE  
200 feet max (61 m)  
Figure 2c – Example C  
EXAMPLE C  
ADDING AN IR RECEIVER TO A ZONE WITH A MRC44 KEYPAD  
This is applicable if the IR Receiver needs to be in a different location than the Keypad/s or if a “CFL Friendly” or “Plasma  
Friendly” IR Receiver is required.  
1. Mount MRC44CB1 to a convenient location using the Adhesive strip supplied  
2. If only one IR Receiver is to be added, you may power this from the MRC44 Controller. In this case, place a jumper  
across JP1 on the MRC44CB1 connecting block.  
3. From the Primary MRC44 Keypad, run a CAT5 cable to where the IR Receiver will be located.  
4. Properly terminate both ends of the cable with RJ45 connectors. Plug one end into the connector labeled Expansion  
on the MRC44 Keypad and the other end into the connector labeled Controller on the MRC44CB1 connecting block.  
5. If IR Receiver is equipped with a “quick connect” 3.5mm connector, plug directly into the jack labeled IR IN on the  
MRC44CB1. If the IR Receiver has “stripped” ends, plug the appropriate wires into the V, G, and S terminals.  
6. If another MRC44 Keypad is being used, run another CAT5 cable from the MRC44CB1 connecting block to the  
location of the next keypad and properly terminate both ends with RJ45 Connectors  
7. Plug one end into the connector labeled Keypad on the MRC44CB1 and the other end into the connector labeled  
Controller on the MRC44 Keypad  
Note: If the overall distance between the MRC44 Controller and the last Keypad in the line is greater than 200ft.,  
an external power supply will be needed. In this case, remove the jumper across JP1 and use a 782-00 Power  
Supply connected to the MRC44CB1 connecting block.  
© 2002 Xantech Corporation  
 
Page 4  
Model MRC44CB1  
781RG Power Supply  
IR Receiver  
400 feet max (122 m)  
MRC44CB1  
CONTROLLER  
KEYPAD  
LED1  
D
JP1  
POWER  
POWER  
MRC44  
POWER  
1
2
3
4
CH  
VOL  
VOL  
CH  
CH  
VOL  
VOL  
PAUSE  
PAUSE  
FOUR ZONE - FOUR SOURCE AUDIO/VIDEO CONTROLLER/AMPLIFIER  
SELECT  
PLA  
SELECT  
PLA  
CH  
Y
Y
REW  
FF  
REW  
FF  
STOP  
STOP  
STATUS  
MUTE  
STATUS  
MUTE  
600 feet max (183 m)  
Figure 2d – Example D  
EXAMPLE D  
EXTENDING THE OVERALL LENGTH BETWEEN MRC44 KEYPADS  
This is applicable when the overall distance between the MRC44 Controller and the last MRC44 Keypad in the chain is greater  
than 200ft.  
1. Remove the jumper across JP1 on the MRC44CB1 connecting block  
2. From the Primary MRC44 Keypad, run a CAT5 to the location where the MRC44CB1 connecting block will be  
located.  
Note: The Primary Keypad must be within 400ft of the MRC44 Controller  
3. Mount MRC44CB1 to a convenient location using the Adhesive strip supplied  
4. Properly terminate both ends of the cable with RJ45 connectors. Plug one end into the connector labeled Expansion  
on the MRC44 Keypad and the other end into the connector labeled Controller on the MRC44CB1 connecting block.  
5. Run another CAT5 cable from the MRC44CB1 connecting block to the location of the next keypad (up to 250 ft.) and  
properly terminate both ends with RJ45 Connectors  
6. Plug one end into the connector labeled Keypad on the MRC44CB1 and the other end into the connector labeled  
Controller on the MRC44 Keypad  
7. Plug a 782-00 Power Supply into the 2.5mm Coaxial jack on the MRC44CB1 connecting block labeled PWR  
CAUTION! Do not plug in a 781RG or any other Power Supply into the MRC44CB1 when a jumper is placed across JP1.  
TROUBLESHOOTING  
1. Power Supply getting warm:  
a. When using external power supply, make sure jumper is removed from JP1 on the MRC44CB1 Connecting  
Block  
b. Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations  
2. IR Receive Confirmation LED lights on MRC44CB1 when IR signal transmitted, but emitters do not flash at MRC44 and  
no control of external sources. All control works fine when controlling from MRC44 Keypads.  
a. CAT5 RJ45 connection at last keypad is plugged into EXPANSION connector instead of KEYPAD  
b. Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations  
3. Still getting IR Interference even when using “CFL Friendly” or “Plasma Friendly” IR Receiver:  
a. IR Receiver on MRC44 Keypads needs to be disabled. Remove jumper across Sensor Enable pins on rear of  
MRC44 Keypad (refer to MRC44 Instruction Manual)  
b. Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations or interference  
from adjacent cable runs, Dimmer Controls etc.  
XANTECH CORPORATION  
12950 Bradley Avenue, Sylmar CA 91342-3829  
phone 818.362.0353 • fax 818.362.9506  
Part No. 08901185 Rev B 09-04-2003  
 

Weider Home Gym 831153922 User Manual
West Bend Rice Cooker 88010 User Manual
Westinghouse Microwave Oven WCM11100SSB User Manual
Whirlpool Cooktop W10162166A User Manual
Whirlpool Oven R82200XK User Manual
Woodstock Saw W1811 User Manual
Yamaha Guitar AEX 500NS User Manual
Zanussi Cooktop FH10 User Manual
Zanussi Freezer ZEF 90 W User Manual
Zanussi Refrigerator ZT 45 30 User Manual